织梦dedecms大气智能环保设备类网站模板(带手机端)-跟版网
Location: Home  > Products  > Solid Densitometer  > Ceramic  > MZ-C3000 High Capacity Bulk Density Porosity Water And Absorption Tester For Ceramic

MZ-C3000 High Capacity Bulk Density Porosity Water And Absorption Tester For Ceramic

Electronic Bulk Density Porosity Water And Absorption Tester For Ceramic

Standard specification:


According to GB/T2413, 1966, 2834, ASTM C20/C134/C373/C329, EN-725, it can be applied to the boiling method, vacuum saturation method, and wax sealing method measurement. According to the principle of Archimedes buoyancy, fast fead the measured value.


Application

Test the density, water absorption and porosity of porous ceramics, dense ceramics, alumina, zirconia, powder, etc.


MZ-C300/C600

Accuracy:0.001g/cm³

MZ-C150 (Equipped with wind and dust cover)

Accuracy:0.0001g/cm³

Patented product: Intelligent MAY-ENTRIS120 series

Accuracy:0.0001g/cm³ 

It can measure 10 sets of samples at a time

MZ-C3000 (Size can be customized as required)

Accuracy: 0.001g/cm³



Features

1. Digital display direct reading, without manual calculation, direct display of density and volume.

2. Porous ceramics, dense ceramics, powders and other similar products can be quickly measured.

3. The German original HBM sensor is used for accurate measurement, easy operation, stable and durable.

4. It has the function of actual water temperature compensation, which can adapt to changes in the test environment.

5. The density of the medium can be set, water is used as the medium, and other liquid mediums can also be used.

6. Adopting one-piece high-capacity measuring platform, corrosion-resistant and drop-proof, free replacement for life.

7. Mayzun-Smart multi-sample measurement system is optional, which can measure 10 sets of data at a time to achieve high-efficiency measurement. One-key printing of A4 standard data reports can store more than 100,000 sets of data.

8. Equipped with a special wind-proof and dust-proof cover, which is easy to combine and durable.

9. With RS-232C communication interface, it is convenient to connect PC and printer. MZ-P1 printer can be selected to print measurement data


MZ-C150 function description


Function 1: For ceramic products with pores and water absorption, it can directly read volume density (media method), apparent density, wet density, apparent porosity, water absorption, open pore volume, closed pore volume, and total porosity.

Function 2: For ceramic products with pores and water absorption, the volume density can be directly read (sealing wax method).

Function 3: For non-porous and non-absorbent ceramic products, the density of the product can be directly read

Function 4: For powder samples, a dedicated pycnometer can be configured to directly read the true density of the powder.



MZ-C300/C600/C3000 function description

Function 1: For ceramic products with pores and water absorption, the volume density (media method), volume density (sealing wax method), apparent density, wet density, apparent porosity, and water absorption can be directly read.

Function 2: For ceramic products that do not absorb water, the density of the product can be directly read.

Function 3: For powder samples, a dedicated pycnometer can be configured to directly read the true density of the powder.



Technical parameters

(Note: A large range of large-scale density meters can be customized according to customer needs, and the maximum can be customized 6-30kg)


Brand

MAYZUM  ( Warranty period: three years)

Model

MZ-C300/MZ-C600

MZ-C1200/MZ-C3000

MZ-C150

 Intelligent 

MAY-ENTRIS120

Max load

300g / 600g

1200g / 3000g

150g

120g

Measuring efficiency

Only one set of samples can be tested at a time

Ten sets of samples can be tested at a time

Density accuracy

0.001 g/cm3

0.0002 g/cm3

0.0001 g/cm3

Density range

0.001~99.999g/cm3

Water absorption

Water absorption, porosity 0.01%

Measurement type

Porous ceramics, dense ceramics, powders and other similar products

Measuring principle

Archimedes drainage method principle

Reading response time

About 2 seconds

Measurement procedure

1. Put it on the measuring table and press the save button to remember;

2. Put the hanging basket in the water and press the save button to display the density and volume directly

The test procedure of porous materials is based on the national standard, please refer to the random manual


The display results 

Bulk density (media method), apparent density, wet density, apparent porosity, water absorption, open pore volume, closed pore volume, total porosity; true density of powder.

Parameter setting

Water temperature setting, medium liquid density setting

Correction method

One-key automatic correction

Output method

RS-232C standard communication interface, convenient for test data output and printing

Temperature and humidity range

Allowable ambient temperature: 0~45℃; Allowable relative humidity: within 80%

Power supply

AC~220V / 50HZ

Operation panel

Japan Omron mechanical keys

Standard accessories

①Host computer, ②Sink, ③Measuring table, ④Tweezers, ⑤Bubble dropper, ⑥Weight, ⑦Power transformer, ⑧Particle measuring accessories, ⑨Floating material measuring accessories

Optional accessories

MZ-P1 printer

MAYZUM-Smart multi-sample measurement system

Other parameters

Outer packing size: 395*195*330mm;

Body size: 210*195*185mm

Net weight of the whole machine: 3.5kg;

Gross weight: 4.5kg

HS code: 90160090)


Intelligent MAY-ENTRIS120 (Equipped with May-D70 data processor) measuring system preview



A4 report is automatically generated after the measurement is completed: